The all-in-one integrated chilled water solution for data center cooling. APC air-cooled chillers provide the most efficient solution for large data center environments. Air cooled chillers afford placement flexibility while supporting both Row and Room cooling products.
The modular air cooled chillers for air conditioning equipment in data centers is a new generation of leading edge technology with an all-in-one integrated package simplifying time and cost of installation.
Precision environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications referred to as technology rooms.
Critical environment applications include:
- Computer rooms
- Telecommunication facilities
- Clean rooms
- Power Equipment
- Medical equipment rooms
- Archives
- LAN/WAN environments
Model
The air cooled modular chillers are designed for medium to large data centers and are available in six models; from 50 kW to 220 kW. Models 50-167 kW include a separate power feed to the pump for UPS connection.
Chilled Water Distribution
Chilled water is often used in data centers to provide the maximum reliability and capacity control of the cooling equipment, while maintaining the indoor environment refrigerant-free. To provide high reliability for year-round operation, a dedicated chiller is recommended for data center air conditioners.
APC’s Air Cooled Modular Chiller supplies chilled water to the Computer Room Air Conditioners (CRACs). The chilled water absorbs rejected heat from the air through the CRAC units and then is routed back to the chiller through the return lines. The chiller then rejects the heat from the water completing the system cycle.
Features & Benefits
FEATURES | BENEFITS |
Manageability | |
Microprocessor Control | Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. |
Total Cost of Ownership | |
Variable speed fans | Variable speed fans reduce energy consumption during off-peak cooling periods. |
In-Row architecture | Includes all the necessary components to make one connection to the chiller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment. |
Availability | |
Scroll Compressors | Utilize few moving parts for increased reliability and life expectancy. |
To learn more about PTS Data Center Solutions available to support your Data Center Management and Monitoring needs, contact us or visit:
- PTS Data Center Planning & Pre-Design
- Computational Fluid Dynamics (CFD) Services
- Data Center Energy Usage Assessment Service
- Data Center Power & Cooling Systems Analysis
- Data Center Availability & Risk Assessment
- Data Center Design Commissioning
- Data Center Support Infrastructure Equipment Services
- Raised Floor Cooling Analysis
- The Challenges of Data Center Cooling
- Help With High Density Cooling