InfraStruxure InRow OA Pumped Refrigerant Data Center Cooling Solutions closely couple the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in overhead or floor mounted configurations, these products are designed to reduce power and whitespace consumption without introducing chilled water next to IT equipment. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Pumped Refrigerant products. The intelligent controls of the InRow Pumped Refrigerant products actively adjust fan speed and refrigerant flow, with no minimum loading, to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments provide high capacity precision air conditioning to maximize cooling for high efficiency operation.

Features & Benefits

FEATURES BENEFITS
Availability
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack Inlet Control Rack inlet control guarantees inlet temperature to IT equipment.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
No minimum heat load requirement Cooling system will operate from 0 – 100% of the design capacity.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Serviceability
Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.
Manageability
Real-Time Capacity Monitoring Real-time display of current and available cooling.
Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.