InfraStruxure InRow RC Chilled Water Data Center Cooling Solutions provide high capacity precision air conditioning to maximize cooling for high efficiency operation. InRow RP is a modular air conditioning unit that is available in either a DX (ACRP100 series) or a chilled water (ACRP500 series) model. It is the width of a standard enclosure, and can be placed in a data-center row. It provides full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP, HTTPS, FTP, Secure Copy (SCP), SMTP, Modbus, and SNMP.

  • Electric Reheat: Prevents overcooling during dehumidification.
  • Humidifier: Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.
FEATURES BENEFITS

Availability

Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.

Agility

Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Casters Provides flexibility to move the unit to wherever cooling is required.

Serviceability

Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.

Manageability

Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.