Stulz-CRAC-CyberAir-Cooling-Solution

The CyberAiR 2 precision air-conditioning system with DFC conditions the air in large computer and equipment rooms with a heat load of over 20 kilowatts up to 60 % more economically than conventional compressor cooling systems.

CyberAiR 2 is the world’s first precision air-conditioning system that considers heat load in computer rooms and seasonally varying ambient temperatures. It automatically selects the optimal operation mode for each case. In cool weather, the optional DFC automatic air-conditioning technology makes use of thrifty dynamic free cooling with outside air. Energy-intensive compressor cooling (DX) is only switched on when absolutely necessary. For this purpose, all units are equipped with speed-controlled EC fans and electronic expansion valves.

In addition to the DFC version described above, STULZ also offers the CyberAiR 2 series in the versions A, G, GE, ACW, GCW, CW and CW2. CyberAiR 2 units are available in six sizes. They require floor space 1000 mm to 2900 mm wide and only 890 mm deep. And the planner has a choice of three coolants – R407C, R410A or R134a.

Features & Benefits

FEATURES BENEFITS
Control by microprocessor Each unit has its own electronic controller. The C7000 microprocessor controls all active components.
Seven cooling systems From a choice of seven cooling systems, data center operators will find the optimum balance between investment, running costs, and energy efficiency. All systems are available as both up-flow and down-flow versions.
Save space and energy Units are produced both as a space-saving standard version and an energy-optimized low-energy version
Three different refrigerants In addition to water as the cooling medium, the devices can run with three different refrigerants R407C, R410A, and high temperature refrigerant R134a.

CyberAiR 2 DX and Dual-Fluid Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/ACW/GCW
Direction of air Down-flow / up-flow
Sizes 1-3

CyberAiR 2 DX and Dual-Fluid Units, dual-circuit

Cooling capacity 40 kW to 105 kW
Cooling systems A/G/ACW/GCW
Direction of air Down-flow / up-flow
Sizes 3-5

CyberAiR 2 LowNoise DX and GE Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/GE
Direction of air Down-flow / up-flow
Sizes 2-4

CyberAiR 2 LowNoise DX Units, dual-circuit

Cooling capacity 41 kW to 73 kW
Cooling systems A/G
Direction of air Down-flow / up-flow
Sizes 4-5

Dimensions (WxHxD in mm)

Size 1 1000 x 1980 x 890
Size 2 1400 x 1980 x 890
Size 3 1750 x 1980 x 890
Size 4 2150 x 1980 x 890
Size 5 2550 x 1980 x 890
Size 7 2900 x 1980 x 890